Home » Case Studies » Vaillant

Vaillant

Vaillant had used Elgood Industrial Flooring over 10 years ago to coat the old concrete floors.

We entered the tendering process and won the contract due to our unique product and emphasis on obtaining the best value for Vaillant.

Installation Programme: two phases to fit with Vaillant’s fit out schedule.

Flooring selected: Elgood Industrial Flooring’s Britdura 1000 A/S Solvent Free Epoxy Floor Coating in the colour Slate Grey. Additional colours included Traffic Blue and Yellow. The coating has a fine slip resistant finish for safety and appearance.

Ecological
We have always been able to confidently over lay our existing floorings thereby minimizing waste.

We reuse our packaging and use only solvent free Epoxy resin.

Facts & Figures
  • Location: Derbyshire
  • Completion date: February and March 2012
  • Size of floor: Approximately 1,200 sqm
  • Product: Britdura 1000
Needs
As part of an investment programme in a New Production Line, Vaillant required a floor with ESD properties.
Preparation
The floor was aggressively scrub cleaned to reduce the silicone contamination. The floor was sealed with our low viscosity primer. This provided a clean silicone free base coat.
Floor
ELGOOD “BRITDURA” ESD FLOORINGS TO BS EN 61340-5-1:2007

BRITDURA ESD FLOORING conforms to the above specification.

Each installation is carried out by Elgood Industrial Flooring Ltd and includes the necessary copper earthing strip laid within the flooring and taken to one or more earth points as required by the client.

BRITDURA ESD FLOORING complies with the BS standard, the relevant section is detailed below:

Please see extract from BS 61340-5-1; 2007

5.3.2 Personnel grounding All personnel shall be grounded or equipotentially bonded according to the requirements below when handling ESDS. When personnel are seated at ESD protective workstations, they shall be connected to ground via a wrist strap system. For standing operations, personnel can be grounded via a wrist strap system or by a flooring foot wear system. When a flooring-footwear system is used, either of the two following conditions shall be met: – the total resistance of the system (from the person, through the footwear and flooring to equipment ground) shall be less than 3,5 X107 Ω;

Vaillant Group
Rob - IMBE-E - Site Services Manager? Vaillant Group
Just a quick thank you for the works carried out at the weekend. Absolutely superb. Looks great and just what was required. The extra repair down by 3HR is very much appreciated also. Thanks again
Find out more about our professional floors – or get a quick quote today